pH dependant coating for microfluidics devices

ผู้แต่ง

  • Luxsana Limsavarn Faculty of Science, Chulalongkorn University
  • Chatr Panithipongwut Faculty of Science, Chulalongkorn University
  • Prangthong Thongkorn Faculty of Science, Chulalongkorn University
  • Stephan T. Dubas Metallurgy and Materials Science Research Institute, Chulalongkorn University

คำสำคัญ:

Microfluidics, polyelectrolyte multilayers, EOF, PDMS.

บทคัดย่อ

The layer-by-layer technique was used to coat the channels of PDMS microfluidics devices. The coating was based on the sequential deposition of polydiallyldimethylammonium chloride (PDADMAC) with a copolymer of polystyrene sulfonate and maleic acid (CoPSS-Maleic) into polyelectrolyte multilayer (PEM). The possible deposition of PEM coating on PDMS was confirm by contact angle which showed the clear transformation of the PDMS surface from hydrophobic to hydrophilic. The later deposition of the PEM coating inside the micro-channels was confirmed by change in electroosmotic flow direction (EOF) and intensity as a function of the number of deposited layers. The EOF measurements revealed that after the deposition of only 2 layers, the flow direction and intensity already reached its maximum value oscillating between –2.5x10-4 cm2/V.S and 4.1x10-4 cm2/V.S as a function of the positive or negative top layers of the coating. The changes in EOF value as a function the pH in the solution were also investigated. The intensity of the electroosmotic flow was influenced by the pH of the solution, which affects the charge density at the surface of the PEM coating. This property can be used to tune the separation resolution, which is the missing parameter in uncoated PDMS chip.

Downloads

Download data is not yet available.

เอกสารอ้างอิง

Linder, V., Verpoorte, E., Thormann , W., de Rooij, N. F. and Sigrist, H. 2001. Surface biopassivation of replicated poly (dimethylsiloxane) microfluidic channels and application to heterogeneous immunoreaction with on-chip fluorescence detection. Anal. Chem. 73(17) : 4181 – 4189.

Quanguo, H., Zhengchun, L., Pengfeng, X., Rongqing, L., Nongyue, H. and Zuhong, L. 2003. Langmuir. 19 : 6982.

Bodas, D. and Khan-Malek, C. 2006. Formation of more stable hydrophilic surface of PDMS by plasma and chemical treatments. Microelectron. Eng. 83(4-9) : 1277 – 1279.

Park, H.B., Han, D.W. and Lee Y.M. 2003. Effect of a UV/ozone treatment on siloxanecontaining copolyimides : Surface modification and gas transport characteristics. Chem. Mater. 15(12) : 2346 – 2353.

Efimenko K., Wallance, W.E. and Genzer, J. 2002. Surface modification of sylgard-184 poly(dimethylsiloxane) networks by ultraviolet and ultraviolet/ozone treatment. J. Colloid Interface Sci. 254(2) :306 – 315.

Berdichevsky, Y., Khandurina, J., Guttman, A. and Lo, Y.H. 2004. UV/ozone modification of poly(dimethylsiloxane) microfluidic channels. Sensors Actuators B: Chemical. 97(2-3) : 402 – 408.

Hu, S., Ren, X., Bachman, M., Sims, C.E., Li, G.P. and Allbritton, N.L. 2004. Langmuir. 20 : 5569.

Slentz, B.E., Penner, N.A. and Regnier, F.E. 2002. Capillary electrochromatography of peptides on microfacricated poly (dimethylsiloxane) chips modified by cerium (IV)-catalyzed polymerization. J. Chromatography A.948(1-2) : 225 – 233.

Papra, A., Bernard, A., Juncker, D., Larsen, N.B., Michel, B. and Delamarche, E. 2001. Microfluidic networks made of poly (dimethylsiloxane), Si, and Au coated with polyethylene glycol for patterning proteins onto surfaces. Langmuir. 17(13) : 4090 – 4095.

Xiao, D., Le, T.V. and Wirth, M.J. 2004. Anal. Chem. 76 : 2055.

Roman G. T., Hlaus, T., Bass, K.J., Seelhammer, T.G. and Culbertson, C.T. 2005. Anal. Chem. 77(5) : 1414 – 1422.

Ocvirk, G., Munroe, M., Tang, T., Oleschuk, R., Westra, K. and Harrison, D.J. 1999. Electrophoresis. 21 : 107.

Dou, Y.-H., Bao, N., Xu, J.-J., Meng, F. and Chen, Hong-Yuan. 2004. Eletrophoresis. 25(17) : 3024 – 3031.

Bergstrom, S.K., Edenwall, N., Lavn, M., Velikyan, I., Langstrom, B. and Markides, K.E. 2005. Polyamine deactivation of integrated poly(dimethylsiloxane) structures investigated by radionuclide imaging and capillary electrophoresis experiments. Anal. Chem. 77(3) : 938 – 942.

Barker, S.L.B., Tariov, M.J., Canavan, H. Hickman, J.J. and Locascio, L.E. 2000. Anal. Chem. 72(20) : 4899 – 4903.

Barker, S.L.R., Ross, D., Tarlov, M.J., Gaitan, M. and Locascio, L.E. 2000. Control of flow direction in microfluidic devices with polyelectrolyte multilayers. Anal. Chem. 72(24) : 5925 – 5929.

Bai, X., Roussel, C., Jensen, H. and Girault, H.H. 2004. Eletrophoresis. 25 : 931.

Tachibana, Y., Otsuka, K., Terabe, S., Arai, A., Suzuki, K. and Nakamura, S. 2004. Effects of the length and modification of the separation channel on microchip electrophoresis-mass spectrometry for analysis of bioactive compounds. J. Chromatography A. 1025(2) : 287 – 296.

Liu, Y., Fanguy, J.C., Bledsoe, J.M. and Henry, C.S. 2000. Anal. Chem. 72 : 5939.

Sui, Z.J. and Schlenoff, J.B. 2003. Controlling electroosmotic flow in microchannels with pH-responsive polyelectrolyte multilayers. Langmuir. 19(19) : 7829-7831.

Ro, K.W., Chan, W.J., Kim, H., Koo, Y.M. and Hahn, J.H. 2003. Capillary electrochrongraphy preconcentration of neutral compounds on poly(dimethylsiloxane) microchips. Eletrophoresis .24(18) : 3253 – 3259.

ดาวน์โหลด

เผยแพร่แล้ว

2017-04-16

วิธีการอ้างอิง

[1]
L. Limsavarn, C. . Panithipongwut, P. Thongkorn, และ S. T. Dubas, “pH dependant coating for microfluidics devices”, J Met Mater Miner, ปี 16, ฉบับที่ 2, เม.ย. 2017.

ฉบับ

บท

Original Research Articles