Development of inexpensive device for methanol detection in hand sanitizer gel using manganese-doped zinc sulfide quantum dots modified by N-methylpolypyrrole

ผู้แต่ง

  • Sophanat KHENTHAPHAK Electrochemistry and Optical Spectroscopy Center of Excellence, Department of Chemistry, Faculty of Science, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand
  • Pakorn JULEANG Electronics Technology Department, Faculty of Science, Ramkhamhaeng University, Bang Kapi, Bangkok 10240, Thailand
  • Wanida WONSAWAT Department of Chemistry, Faculty of Science and Technology, Suan Sunandha Rajabhat University, U-Thong Nok Road, Bangkok 10300, Thailand
  • Orawon CHAILAPAKUL Electrochemistry and Optical Spectroscopy Center of Excellence, Department of Chemistry, Faculty of Science, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand
  • Eakkasit PUNRAT Department of Chemistry, Faculty of Science, Ramkhamhaeng University, Bang Kapi, Bangkok 10240, Thailand

DOI:

https://doi.org/10.55713/jmmm.v33i1.1597

คำสำคัญ:

Methanol detection, Manganese-doped zinc sulfide quantum dots, N-methyl polypyrrole, Digital-image colorimetry, Hand sanitizer gel

บทคัดย่อ

A method for methanol detection by an inexpensive device using a nanomaterial modified by N-methylpolypyrrole (NMPPY) has been developed. Manganese-doped zinc sulfide quantum dots (Mn/ZnS-QDs) were synthesized and then characterized by a fluorescence spectrophotometer to study their spectroscopic properties. Mn/ZnS-QDs were modified with NMPPy and studied by digital-image colorimetry to optimize conditions for methanol detection. A 2 mL of 3000 mg∙L–1 Mn/ZnS-QDs modified with 300 μL of 1000 mg∙L-1 of NMPPy was chosen to be a detecting reagent for methanol determination. Under the optimum conditions, the linear range was found to be 2%v/v to 50%v/v of methanol with R-square of 0.9434 and the sensitivity of 3.569 ´ 10–3 (%v/v)-1, whilst the limit of detection (LOD) was 19.5%v/v. The selectivity of this method was also studied with several solvents; it was proven selective for methanol. Furthermore, a prototype device with simple and inexpensive has been created. The analytical performances were studied; the linearity of methanol detection was found in the range of 20%v/v to 80%v/v with R-square of 0.9918 and the sensitivity of 3.38 ´ 10-3 (%v/v)-1. Finally, the newly developed device was applied to analyze samples of hand sanitizer gel by digital-image colorimetry with acceptable results.

Downloads

Download data is not yet available.

เอกสารอ้างอิง

M. Svanberg, J. Ellis, J. Lundgren, and I. Landälv, "Renewable methanol as a fuel for the shipping industry," Renewable and Sustainable Energy Reviews, vol. 94, pp. 94:1217, 2018.

M. A. Kostic, and R. C. Dart, "Rethinking the toxic methanol level," Journal of Toxicology. Clinical Toxicology, vol. 41, pp. 793-800, 2003.

G. Leaf, and L. J. Zatman, "A study of the conditions under which methanol may exert a toxic hazard in industry," British Journal of Industrial Medicine, vol. 9, pp. 19-31, 1952.

S. Baloch, M. A. Baloch, T. Zheng, and X. Pei, "The coronavirus disease 2019 (COVID-19) Pandemic," The Tohoku Journal of Experimental Medicine, vol. 250, pp. 271-278, 2020.

G. C. Martin, G. Le Roux, D. Guindolet, E. Boulanger, D. Hasle, E. Morin, D. Vodovar, C. Vignal, E. Gabison, and A. Descatha, "Pediatric eye injuries by hydroalcoholic gel in the context of the coronavirus disease 2019 pandemic," JAMA Ophthalmology, vol. 139, pp. 348-351, 2021.

W. Sattle, H. Puhl, M. Hayn, G. M. Kostner, and H. Esterbauer, "Determination of fatty acids in the main lipoprotein classes by capillary gas chromatography: BF3/methanol transesterification of lyophilized samples instead of folch extraction gives higher yields," Analytical Biochemistry, vol. 198, pp. 184-190, 1991.

B. Tao, J. Zhang, S. Hui, X. Chen, and L. Wan, "An electro-chemical methanol sensor based on a Pd–Ni/SiNWs catalytic electrode," Electrochimica Acta, vol. 55, pp. 5019-5023, 2010.

B. R. Buchanan, and D. E. Honigs, "Detection of methanol in gasolines using near-infrared spectroscopy and an optical fiber," Applied Spectroscopy, vol. 41, pp. 1388-1392,1987.

M. Nemecek-Marshall, R. C. MacDonald, J. J. Franzen, C. L. Wojciechowski, and R. Fall, "Methanol emission from leaves (enzymatic detection of gas-phase methanol and relation of methanol fluxes to stomatal conductance and leaf development), "Plant Physiology, vol.108, pp. 1359-1368, 1995.

N. G. Patel, P.D. Patel, and V. S. Vaishnav, "Indium tin oxide (ITO) thin film gas sensor for detection of methanol at room temperature," Sensors and Actuators B: Chemical, vol. 96, pp. 180-189, 2003.

M. Rana, and P. Chowdhury, "L-glutathione capped CdSeS/ ZnS quantum dot sensor for the detection of environmentally hazardous metal ions," Journal of Luminescence, vol. 206, pp. 105-112, 2019.

A. P. Alivisatos, "Semiconductor clusters, nanocrystals, and quantum dots," Science, vol. 271, pp. 933-937, 1996.

J. K. Jaiswal, and S. M. Simon, "Potentials and pitfalls of fluorescent quantum dots for biological imaging," Trends in Cell Biology, vol. 14, pp. 497-504, 2004.

W. Bian, J. Ma, W. Guo, D. Lu, M. Fan, Y. Wei, Y. Li, S. Shuang, and M. M. F. Choi, "Phosphorescence detection of L-ascorbic acid with surface-attached N-acetyl-L-cysteine and L-cysteine Mn doped ZnS quantum dots," Talanta, vol. 116, pp. 794-800, 2013.

F. Abbasi, A. Akbarinejad, and N. Alizadeh, "CdS QDs/N-methylpolypyrrole hybrids as fluorescent probe for ultrasensitive and selective detection of picric acid," Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, vol. 216, pp. 230-235, 2019.

F. Abbasi, and N. Alizadeh, "Highly selective detection of methanol in aqueous and ethanol medium based on hybrid ZnS:Mn2+quantum dots/N-methylpolypyrrole as a fluorescence switchable sensor," Food Chemistry, vol. 328, pp.127091, 2020.

A. C. Small, and J. H. Johnston, "Novel hybrid materials of cellulose fibres and doped ZnS nanocrystals," Current Applied Physics, vol. 8, pp. 512-515, 2008.

N. Alizadeh, and A. Akbarinejad, "Soluble fluorescent polymeric nanoparticles based on pyrrole derivatives: synthesis, characterization and their structure dependent sensing properties," Journal of Materials Chemistry C, vol. 3, pp. 9910-9920, 2015.

J. Hottechamps, T. Noblet, A. Brans, C. Humbert, and L. Dreesen, "How quantum dots aggregation enhances Förster resonant energy transfer," ChemPhysChem, vol. 21, pp. 853-862, 2020.

E. Sharon, R. Freeman, M. Riskin, N. Gil, Y. Tzfati ,and I. Willner, "Optical, electrical and surface plasmon resonance methods for detecting telomerase activity," Analytical Chemistry, vol. 82, pp. 8390-8397, 2010.

P. Mukoma, B. R. Jooste, and H. C. M. Vosloo, "A comparison of methanol permeability in chitosan and nafion 117 membranes at high to medium methanol concentrations," Journal of Membrane Science, vol. 243, pp. 293-299, 2004.

ดาวน์โหลด

เผยแพร่แล้ว

2023-03-28

วิธีการอ้างอิง

[1]
S. . KHENTHAPHAK, P. . JULEANG, W. . WONSAWAT, O. . CHAILAPAKUL, และ E. . PUNRAT, “Development of inexpensive device for methanol detection in hand sanitizer gel using manganese-doped zinc sulfide quantum dots modified by N-methylpolypyrrole”, J Met Mater Miner, ปี 33, ฉบับที่ 1, น. 82–88, มี.ค. 2023.

ฉบับ

บท

Original Research Articles